Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Braz. dent. j ; 35: e24, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1550084

ABSTRACT

Abstract This study analyzed the physical-chemical properties of bioactive ionomer materials. Cention N bioactive materials were evaluated chemically activated (CN) and light-cured (CN-LC), Equia Forte Fill (EQUI); conventional resin composite Filtek Z350 XT (Z350); resin glass ionomer cement Riva light Cure (RIVA) and flowable resin composite Filtek Bulk Fill Flow (BULK-F) were evaluated. Sixty specimens (n=10) were prepared for sorption (SR), solubility (SL), flexural strength (FS), shrinkage stress (SS), conversion degree (CD), microhardness (MI), and surface roughness (SR) tests. Non-cured and light-cured materials were assessed on FTIR. 30 human molar teeth were used in the bond strength test (BS). Data were subjected to ANOVA and post-hoc Tukey's test (5% of significance). EQUI showed more sorption in SR and no statistical difference from RIVA and CN-LC. CN group showed more solubility and EQUI presented less (p<0.05). BULK-F showed higher FS (MPa), without differences from CN and Z350, whereas EQUI presented the lowest FS not differing from RIVA. BULK-F and CN-LC showed more shrinkage stress differing from EQUI. CN-LC and CN showed higher CD differing from the other which showed no differences (p>0.05) between them. EQUI showed the highest hardness (p<0.05) in MI. There were no differences (p>0.05) in SR (µm). Z350 and BULK-F presented higher BS, whereas CN-LC showed the lowest, although not differing from EQUI and RIVA. Equia Forte's solubility and microhardness make it a good alternative as a restorative material. Cention N degree of conversion and flexural strength making it an esthetic option to amalgam.


Resumo Este estudo analisou as propriedades físico-químicas dos materiais de ionômero bioativo. Os materiais bioativos Cention N quimicamente ativados (CN) e fotopolimerizados (CN-LC), Equia Forte Fill (EQUI); resina composta convencional Filtek Z350 XT (Z350); resina de ionômero de vidro Riva light Cure (RIVA) e resina composta fluida Filtek Bulk Fill Flow (BULK-F) foram avaliados. Sessenta espécimes (n=10) foram preparados para testes de sorção (SR), solubilidade (SL), resistência à flexão (FS), tensão de contração (SS), grau de conversão (CD), microdureza (MI) e rugosidade da superfície (SR). Os materiais não curados e curados com luz foram avaliados por FTIR. 30 dentes molares humanos foram usados no teste de resistência de união (BS). Os dados foram submetidos a ANOVA e teste de post-hoc Tukey (5% de significância). O EQUI apresentou maior sorção no SR e não mostrou diferença estatística em relação aos grupos RIVA e CN-LC. O grupo CN apresentou maior solubilidade e o EQUI apresentou menor (p<0,05). O BULK-F apresentou maior FS (MPa), sem diferir do CN e do Z350, enquanto o EQUI apresentou o menor FS, não diferindo do RIVA. O BULK-F e o CN-LC apresentaram maior estresse de contração, diferindo do EQUI. O CN-LC e o CN apresentaram maior CD (%), diferindo dos demais, que não apresentaram diferenças (p>0,05) entre si. A EQUI apresentou a maior dureza (p<0,05) no MI. Não houve diferenças (p>0,05) na SR (µm). Z350 and BULK-F apresentaram BS, enquanto a CN-LC apresentou a menor, embora não diferindo da EQUI e da RIVA. A solubilidade e a microdureza do Equia Forte o tornam uma boa alternativa como material restaurador. O grau de conversão e a resistência à flexão do Cention N o tornam uma opção estética ao amálgama.

2.
Braz. dent. j ; 33(6): 78-85, Nov.-Dec. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1420562

ABSTRACT

Abstract The aims of this clinical study were to evaluate the Color change - ΔE (based on spectrophotometry and visual analysis) and luminosity - L* (based on spectrophotometry) of dental enamel surface (after orthodontic treatment) around the area where orthodontic brackets were fixed, based on different cementing materials such as a resin (R group) and resin-modified glass ionomer cement (RMGIC group). The split-mouth study initially comprised 14 patients. Orthodontic brackets were fixed to the upper central incisors with resin or RMGIC. The color of the buccal surface of each tooth was measured through spectrophotometry and visual examination before the bracket-fixation process. Four individuals were excluded during the follow-up; thus 10 patients were evaluated (n=10). Brackets were removed after 12 months of orthodontic treatment, tooth color measurement and visual examination were performed again, and Adhesive Remaining Index (ARI) was also measured. ΔE and L* results were subjected to Student's t-test and by repeated-measures analysis of variance, respectively (α=0.05). ARI data were analyzed in percentages. There was statistically significant difference in ΔE between groups; the R group showed statistically higher values of L* after orthodontic treatment. ARI of 2 and 3 prevailed in the RMGIC group, whereas the R group presented 0 and 1. After orthodontic treatment, the RMGIC group presented smaller changes in ΔE, and the increase in the white scale was observed on the enamel surface around the area where brackets were fixed in the R group. The visual analysis did not show color change on the evaluated teeth.


Resumo Os objetivos deste estudo clínico foram avaliar a alteração de cor - ΔE (baseada em espectrofotometria e análise visual) e luminosidade - L* (baseada em espectrofotometria) da superfície do esmalte dentário (após tratamento ortodôntico) ao redor da área onde os braquetes ortodônticos foram fixados, com base em diferentes materiais de cimentação, como resina (grupo R) e cimento de ionômero de vidro modificado por resina (grupo RMGIC). Estudo boca dividida foi inicialmente composto por 14 pacientes. Os braquetes ortodônticos foram fixados nos incisivos centrais superiores com resina ou RMGIC. A cor da superfície vestibular de cada dente foi mensurada por espectrofotometria e avaliada por exame visual antes do processo de fixação dos braquetes. Quatro indivíduos foram excluídos durante o acompanhamento; assim, 10 pacientes foram avaliados (n=10). Os braquetes foram removidos após 12 meses de tratamento ortodôntico, a mensuração da cor do dente e o exame visual foram realizados novamente, e o Índice de Remanescente do Adesivo (IRA) também foi mensurado. Os resultados ΔE e L* foram submetidos ao teste t de Student e à análise de variância para medidas repetidas, respectivamente (α=0.05). Os dados do ARI foram analisados em porcentagens. Houve diferença estatisticamente significativa no ΔE entre os grupos; o grupo R apresentou valores estatisticamente maiores de L* após o tratamento ortodôntico. O IRA 2 e 3 prevaleceu no grupo RMGIC, enquanto o grupo R apresentou 0 e 1. Após o tratamento ortodôntico, o grupo RMGIC apresentou menores alterações no ΔE e o aumento da escala branca foi observado na superfície do esmalte ao redor da área onde os braquetes foram fixados no grupo R. A análise visual não mostrou mudança de cor nos dentes avaliados.

3.
Braz. j. oral sci ; 21: e227878, jan.-dez. 2022. tab
Article in English | LILACS, BBO | ID: biblio-1384155

ABSTRACT

Aim Assessing the intracoronal bleaching effectiveness of an experimental chlorine dioxide product, based on the walking bleach technique. Methods Extracted bovine incisors were artificially stained with bovine blood and filled with zinc phosphate cement at cementoenamel junction level. Teeth were divided into 3 groups (n=10): (SP) sodium perborate added with distilled water, (CD) chlorine dioxide and (C) control - dry cotton inserted into the pulp chamber. Bleaching agents were used at 0, 7 and 14 days. VITA Easyshadetm (∆Eab) was used to analyze tooth color at the 7th, 14th and 21st days, based on the CIE2000 system. Data were analyzed through ANOVA and Tukey's test. Results There were no statistically significant differences in Δb, ΔE, ΔE00 and ΔWID between CD and the control group. These parameters have shown significant differences between CD and SP, which differed from the control. However, they did not show significant differences either in the control group or in CD at the 7th, 14th and 21st days. Values recorded for SP at the 7th day differed from those recorded at the 14th and 21st days. Δa has shown differences within the same group at the 7th, 14th and 21st days. There was no difference between groups, when they were compared at the same day (7th and 14th). The control group differed from SP at the 21st day. CD did not differ from the other two groups. ΔL did not show differences between groups and times. Conclusion Stabilized chlorine dioxide (0.07%, at pH 3.5) should not be used as intracoronal bleaching agent along with the walking bleach technique.


Subject(s)
Tooth Bleaching , Borates , Chlorine Compounds , Dental Materials , Chlorine Dioxide
4.
Braz. dent. j ; 33(5): 74-80, Sep.-Oct. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1403788

ABSTRACT

Abstract The longevity of prosthetic rehabilitation is determined by the stability of the implant and abutment interfaces. True morse taper connections on dental restorations have been effective, however activation force still empirical. This work compared the activation strength and internal contact of Morse taper system according to the removal force. Eighty sets, composed of implants and prosthetic abutments, were evaluated with different internal contact areas; 15.12mm2 (G3.3) and 21.25mm2 (G4.3). The specimens were activated at 0° and 30°, with loads of 10, 20, 40 and 60N. The specimens were submitted to tensile test and the data to ANOVA and Tukey's tests (α=0.05). Representative specimens were examined under SEM. Removal force of G3.3 (2.15±1.33MPa) did not differed to G4.3 (1.99±1.03MPa). The activation at 0º (2.95±0.98MPa) statistically differed to 30º (1.19±0.54MPa). The 60N load was statistically superior for G3.3 and there was no statistical difference between 20N to 60N in G4.3. The values of 10N at 30o and 20N at the long axis of the morse taper implant, independent of the frictional contact area showed the best settlement.


Resumo A longevidade da reabilitação protética é determinada pela estabilidade das interfaces implante e pilar. Conexões de cone Morse em restaurações dentárias têm se mostrado eficazes, porém a força de ativação ainda é empírica. Este trabalho comparou a força de ativação e contato interno do sistema cone Morse de acordo com a força de remoção. Oitenta conjuntos, compostos por implantes e pilares protéticos, foram avaliados com diferentes áreas de contato interno; 15,12mm2 (G3.3) e 21,25mm2 (G4.3). Os corpos-de-prova foram ativados a 0° e 30°, com cargas de 10, 20, 40 e 60N. Os corpos de prova foram submetidos ao ensaio de tração e os dados aos testes ANOVA e Tukey (α=0,05). Espécimes representativos foram examinados em MEV. A força de deslocamento do G3.3 (2,15±1,33MPa) não diferiu do G4.3 (1,99±1,03MPa). A ativação a 0º (2,95±0,98MPa) diferiu estatisticamente para 30º (1,19±0,54MPa). A carga de 60N foi estatisticamente superior para G3.3 e não houve diferença estatística entre 20N a 60N no G4.3. Os valores de 10N em 30o e 20N no longo eixo do implante cone morse, independente da área de contato friccional apresentaram o melhor assentamento.

5.
J. health sci. (Londrina) ; 24(1): 12-16, 20220322.
Article in English | LILACS-Express | LILACS | ID: biblio-1362809

ABSTRACT

Abstract Currently, CAD / CAM systems have been increasingly used in Dentistry, however due to the characteristic of the technique, since it is milled from a ceramic block, some flaws, such as fractures, become a challenge after the piece is cemented. To avoid the complete replacement of the part, the technique through intraoral repair of the fractured region is ideal for these cases. There are several protocols for this technique, this study aims to review the literature regarding the techniques and protocols for ceramic repair of the CAD / CAM system. A literature review was carried out on the Pubmed database using the terms Ceramic repair, Adhesive and Composite resin searching for studies published in the period from 2000 to 2020. 104 articles were found, after reading 32 articles were selected because they presented a greater correlation with the present study. There was unanimity among the authors about the importance of a surface treatment on the ceramic to be repaired, 70% of them still indicated the roughness with drills and conditioning with hydrofluoric acid due to the ease of the technique and good result. The combination of several surface treatments in the same region to be repaired produces better tensile strength. The use of the silane agent in a separate step presents better bonding strength results when compared to the universal type adhesive system with silane incorporated in the formula. (AU)


Resumo Atualmente os sistemas CAD/CAM tem sido cada vez mais utilizados na Odontologia, porém devido a característica da técnica, já que é fresada a partir de um bloco cerâmico, algumas falhas, como fraturas, se tornam um desafio após a peça ser cimentada. Para evitar a completa substituição da peça a técnica através de reparo intraoral da região fraturada é ideal para esses casos. Existem diversos protocolos para esta técnica, este estudo tem por objetivo uma revisão de literatura quanto às técnicas e protocolos de reparo em cerâmica do sistema CAD/CAM. Foi realizada uma revisão de literatura no indexador Pubmed database utilizando os termos Ceramic repair, Adhesive e Composite resin buscando estudos publicados no período de 2000 a 2020. Foram encontrados 104 artigos, após leitura 32 artigos foram selecionados pois apresentavam maior correlação com o presente estudo. Foi unanimidade entre os autores acerca da importância de um tratamento de superfície na cerâmica a ser reparada, 70% deles ainda indicaram a asperização com brocas e condicionamento com ácido fluorídrico pela facilidade da técnica e bom resultado. A associação de vários tratamentos de superfície na mesma região a ser reparada produz melhor resistência a tração. O uso do agente silano em etapa separada apresenta melhores resultados de resistência de união quando comparado ao sistema adesivo do tipo universal com silano incorporado na fórmula. (AU)

6.
Braz. dent. j ; 32(5): 34-40, Sept.-Oct. 2021. tab
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1350285

ABSTRACT

Abstract The aims of this in vivo study were to evaluate the effect of bonding with resin-modified glass ionomer cement (RMGIC) and to assess enamel surface roughness before and after the removal of brackets bonded with composite or RMGIC from the maxillary central incisors. Fifteen orthodontic patients were selected for the study. For each patient, the teeth were rinsed and dried, and brackets were bonded with composite (Transbond XT) and RMGIC (Vitremer Core Buildup/Restorative). At the conclusion of orthodontic treatment, their brackets were removed. Dental replicas were made of epoxy resin in initial conditions (before bonded) and after polishing with an aluminum oxide disc system. Adhesive remnant index (ARI) and surface roughness was measured on the dental replicas and data were evaluated statistically by Mann-Whitney and paired t-test, respectively. No bracket debonding occurred during patients' treatment periods. It was verified that the ARI values of the two maxillary central incisors were similar (p = 0.665). For both bonding materials, the ARI value of 3 was predominant. After polishing, surface roughness was similar in the composite and RMGIC groups (0.245 μm and 0.248 μm, respectively; p = 0.07). In both groups, enamel surface roughness values were significantly lower after polishing compared with the initial condition (p < 0.001). RMGIC promoted efficiency in cementing brackets without fail during treatment; the choice of composite or RMGIC materials was not a factor that influenced the roughness of the enamel surface, however, polishing led to smoother surfaces than those found at the beginning of the treatment.


Resumo Os objetivos deste estudo in vivo foram avaliar o efeito da colagem com cimento de ionômero de vidro modificado por resina (CIVMR) e a rugosidade da superfície do esmalte antes e após a remoção dos braquetes colados com compósito ou CIVMR em incisivos centrais superiores. Quinze pacientes ortodônticos foram selecionados para o estudo. Para cada paciente, os dentes foram lavados e secos, e os braquetes colados com compósito (Transbond XT) e CIVMR (Vitremer Core Buildup / Restorative). Ao término do tratamento ortodôntico, os braquetes foram removidos. As réplicas dentais foram confeccionadas em resina epóxica nas condições iniciais (antes da colagem) e após o polimento com sistema de discos de óxido de alumínio. O índice de remanescente adesivo (IRA) e a rugosidade da superfície foram mensurados nas réplicas dentais e os dados foram avaliados estatisticamente por Mann-Whitney e teste t pareado, respectivamente. Não ocorreu descolagem de braquetes durante os períodos de tratamento dos pacientes. Verificou-se que os valores do IRA dos dois incisivos centrais superiores foram semelhantes (p = 0,665). Para ambos os materiais de colagem, o valor de IRA predominante foi 3. Após o polimento, a rugosidade da superfície do esmalte foi semelhante nos grupos compósito (0,245 μm) e CIVMR (0,248 μm) (p = 0,07). Em ambos os grupos, os valores de rugosidade da superfície do esmalte foram significativamente menores após o polimento em comparação com a condição inicial (p <0,001). CIVMR promoveu eficiência na colagem de braquetes sem falhas durante o tratamento; a escolha dos materiais compósito ou CIVMR não foi um fator que influenciou na rugosidade da superfície do esmalte, porém, o polimento levou a superfícies mais lisas do que as encontradas no início do tratamento.

7.
J. health sci. (Londrina) ; 23(2): 136-140, 20210621.
Article in English | LILACS-Express | LILACS | ID: biblio-1283126

ABSTRACT

Endodontic treatment is common in dentistry and for a correct diagnosis it is necessary to observe clinical and radiographic signs, taking into account pulp and periapical changes in the element to be treated. Studying this frequency can contribute to the literature, elucidating whether the greatest number of cases is occurring in young or elderly patients, women or men, anterior or posterior teeth. The objective of this study was to analyze the prevalence of endodontically treated teeth, through 900 panoramic radiographs. A cross-sectional study was carried out evaluating the prevalence of teeth treated endodontically from a sample of 900 panoramic radiographs, corresponding to exams performed in 2020, in a radiological clinic located in central west Brazil. The sample consisted of 540 (60%) female subjects and 360 (40%) male subjects, aged between 18 and 88 years old, being more prevalent for Individuals <31 years old with (34.9%) Sample. The prevalence of endodontically treated teeth was analyzed, the results showed 1,236 teeth in this condition, individually analyzing the upper right central incisor was the most frequent 9.22%, while for group analysis the upper teeth were 7.06%. Therefore, there was a higher prevalence of teeth treated endodontically in the maxilla, the tooth with the highest treatment index, the right upper central incisor. Women were more affected and it was observed that with increasing age, the number of teeth treated endodontically also increases. (AU)


O tratamento endodôntico é frequente na odontologia e para um correto diagnóstico é necessário observar sinais clínicos e radiográficos, levando em consideração as alterações pulpares e periapicais no elemento à ser tratado. Estudar essa frequência pode colaborar com a literatura, elucidando se o maior número de casos está ocorrendo em pacientes jovens ou idosos,mulheres ou homens, dentes anteriores ou posteriores O objetivo desse presente estudo foi analisar a prevalência de dentes tratados endodônticamente, por meio de 900 radiografias panorâmicas. Foi realizado um estudo transversal avaliando prevalência de dentes tratados endodônticamente a partir de uma amostra de 900 radiografias panorâmicas, correspondentes a exames realizados em 2020, em uma clínica radiológica situada no centro oeste do Brasil. A amostra foi constituída por 540 (60%) Indivíduos do gênero feminino e 360 (40%) do masculino, com idade entre 18 e 88 anos de idade, sendo mais prevalente para Indivíduos <31 anos de idade com (34,9%) da amostra. Foi analisada a prevalência de dentes tratados endodônticamente, os resultados mostraram 1.236 dentes nesta condição, analisando individualmente o incisivo central superiores direito foi o mais frequente 9,22%, enquanto para análise de dentes por grupos foram os dentes anteriores superiores 7,06%. Portanto, houve uma maior prevalência de dentes tratados endodônticamente em maxila, o dente com maior índice de tratamento o incisivo central superior direito. Mulheres foram mais acometidas e observou-se que com o aumento da idade, aumenta-se também o número de dentes tratados endodônticamente. (AU)

8.
Braz. dent. j ; 31(4): 440-444, July-Aug. 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1132310

ABSTRACT

Abstract Posterior build-ups are auxiliary devices to orthodontic treatment which are made with resin-based or glass ionomer composites. Their removal requires care to protect the tooth surface, therefore, pigmented materials are preferred for a better visualization. This study proposed a pigmentation experimental technique of a regular composite resin, evaluating the microshear bond strength test (µ-SBT) of this experimental pigmented resin and comparing with a blue-colored polyacid-modified composite resin, used for posterior buildups. Forty-eight buccal and lingual surfaces of human teeth were used and randomly divided into 4 groups (n=12). The groups were divided into: C (control), regular composite resin; P, regular composite resin pigmented; UBL, Ultra Band Lok™; OB, Ortho Bite™. The composites were bonded using a matrix to obtain microcylinders and prepared for each experimental groups. The samples were then stored in distilled water for 24h at 37°C followed by a µ-SBT. The types of bond failures were evaluated using a stereoscopic magnifying glass (10×). The data were analyzed by ANOVA with Fisher post hoc and Dunnett´s test. Means of µ-SBT± standard deviation (MPa) were: C (39.98a±13.0), P (40.09a± 14.3); UBL (33.26ab±8.6); OB (28.70b±5.5). The most prevalent type of failure was adhesive (80.4%). Further, was not observed a statistically significant correlation between the bond strength values and failure patterns. The pigmentation of a commercially available resin did not alter the µ-SBT and exhibited similar adhesiveness as a polyacid-modified composite resin.


Resumo Levantes de mordida posterior são dispositivos para o tratamento ortodôntico confeccionados com resinas compostas ou materiais ionoméricos. Cuidado com a remoção destes se faz necessário para proteção da superfície dentária; para tanto, materiais pigmentados são preferidos por proporcionar melhor visualização. Este estudo propõe uma técnica de pigmentação experimental de resinas compostas convencionais, avaliando a resistência ao microcisalhamento (µ-SBT) na interface de união da resina experimental e superfície de esmalte dental e comparando-a com materiais comercialmente disponíveis para a confecção de levantes de mordida. Quarenta e oito superfícies de dentes humanos foram selecionadas aleatoriamente e divididos em quatro grupos (n=12), de acordo com o material adesivo utilizado: C (Controle, resina composta convencional); P (pigmentação experimental da resina composta convencional); UBL (Ultra Band Lok®); OB (Ortho Bite®). Microcilindros foram preparados para cada tipo de compósito utilizando uma matriz de silicone. As amostras foram mantidas em água destilada por 24h a 37°C, antes da realização do µ-SBT. Os padrões de fratura foram avaliados através de uma lupa estereoscópica com magnificação de 10x. ANOVA com pós teste de Fisher e teste de Dunnett foram utilizados para avaliar os dados. As médias obtidas do µ-SBT ± desvio padrão (MPa) foram: C (39.98a±13.0), P (40.09a± 14.3); UBL (33.26ab±8.6); OB (28.70b±5.5). O tipo de fratura mais prevalente foi a adesiva (80.4%). Além disso, não foi observada correlação estatisticamente significante entre os valores de resistência de união e os padrões de fratura. A técnica de pigmentação experimental não alterou os resultados de µ-SBT da resina composta convencional e mostrou adesividade semelhante à dos compósitos modificados por poliácidos utilizados neste estudo.


Subject(s)
Humans , Dental Bonding , Composite Resins , Materials Testing , Pigmentation , Resin Cements , Glass Ionomer Cements
9.
J. health sci. (Londrina) ; 20(3)31/10/2018.
Article in English | LILACS | ID: biblio-965466

ABSTRACT

Brazilian health care programs recommend the use of cariostatic solutions of silver diamine fluoride (SDF) or sodium fluoride varnishes for children 0 to 3 years old with high or moderate caries activity for the control of caries lesions. SDF is a safe, economical, efficient and non-invasive coadjuvant agent, exerting an antibacterial action capable of reducing superficial mineral loss of the enamel and can be used in the treatment of deciduous and permanent teeth. The objective of this literature review was to gather current information on describing the mechanism of SDF action' and its clinical application in young children in caries prevention and paralysis. The PubMed / Medline and Cochrane Library databases were accessed by identifying the relevant studies published in English from 1960 to May 2017. The search strategy employed the keywords: "Silver diamine fluoride" and "Children "or "Infant" and "Caries prevention". Data extraction was performed in: 19 in vitro studies; 10 review articles and 8 in vivo studies. It was possible to conclude that SDF is almost twice as effective compared to fluoride varnish in caries paralysis. However, the contact time of the solution and the optimal frequency of application of the SDF are still undefined, inducing new projects and clinical studies in the search for an adequate clinical protocol of this cariostatic.(AU)


Os programas de assistência à saúde brasileiros recomendam para o controle das lesões de cárie a utilização de soluções cariostáticas de diamino fluoreto de prata - DFP ou vernizes de fluoreto de sódio para crianças de 0 a 3 anos com atividade de cárie alta ou moderada. O DFP é agente coadjuvante seguro, econômico, eficiente e não invasivo, exercendo ação antibacteriana capaz de reduzir a perda mineral superficial do esmalte e, pode ser utilizado no tratamento de dentes decíduos e permanentes. O objetivo desta revisão de literatura foi reunir informações atuais sobre descrever o mecanismo de ação do DFP e sua aplicação clínica em crianças de pouca idade na prevenção e paralisação da cárie. As bases de dados PubMed/Medline e Cochane Library foram acessadas identificando os estudos relevantes publicados em inglês, no período de 1960 a maio de 2017. A estratégia de busca empregou as palavras-chave: "Silver diamine fluoride" and "Children" or "Infant" and "Caries prevention". A extração dos dados foi realizada em: 19 estudos in vitro; 10 artigos de revisão e 8 estudos in vivo. Foi possível concluir que o DFP apresenta-se quase duas vezes tão eficaz comparado ao verniz fluoretado na paralização de cárie. Porém, o tempo de contato da solução e a frequência ótima de aplicação do DFP ainda estão indefinidos, suscitando novos projetos e estudos clínicos na busca de adequado protocolo clínico deste cariostático.(AU).

10.
Braz. j. oral sci ; 17: e181207, 2018. tab
Article in English | LILACS, BBO | ID: biblio-970477

ABSTRACT

Aim: The aim of this study was to evaluate and compare the setting times (ST), flow (FW), radiopacity (RP), dimensional stability (DS), solubility (SB), and polymerization stress (PS) of the MTA Fillapex and AH Plus root canal sealers. Methods: The above qualities were tested according to ISO 6876/2001 standardization. The water used in the dimensional stability test was evaluated to verify the presence of released materials. For the photoelastic analysis, 20 photoelastic resin rings were prepared, and the root canal sealers were inserted. After 24 hours, the specimens were analyzed in a Polariscope. Data of the setting times, flow tests, radiopacity, dimensional stability, and solubility tests were submitted to a Kolgomorov­Smirnov test and then to a Student's t-test at the 5% significance level. Results: The data derived from photoelastic analyses were submitted to an ANOVA and Tukey's test with a significance level of 5%. MTA Fillapex and AH Plus complied with ISO 6876/2001. However, there were significant differences (p < 0.05) between the two cements for ST, FW, RP, DS, and SB. MTA Fillapex showed higher FW, SB, and PS when compared with AH Plus. Conclusions: MTA Fillapex and AH Plus complied with ISO 6876/2001 in terms of ST, FW, RP, DS, and SB. MTA Fillapex showed higher PS when compared to AH Plus


Subject(s)
Root Canal Obturation , Surface Properties , Dental Materials , Endodontics
11.
Acta odontol. latinoam ; 31(3): 144-148, 2018. ilus, tab
Article in English | LILACS | ID: biblio-987525

ABSTRACT

The purpose of this study was to describe and characterize (using the tensile test) an alternative handling technique for calcium hydroxide cement in temporary crown cementation. In the group treated with the conventional technique (n=10), the base and catalyst pastes of a calcium hydroxide cement (Dycal) were dispensed at a 1:1 ratio and mixed. The cement was then applied to the internal cervical surfaces of the provisional restoration, and the restoration was placed on the prepared tooth and kept in place with digital pressure. In the group treated with the alternative technique (n=10), the base paste of the calcium hydroxide cement (Dycal) was placed on the tooth and the catalyst paste was inserted into the temporary crown. The provisional prosthesis was placed on the tooth and kept in place with digital pressure. Tensile values were evaluated and compared between groups using Student's t test with a 5% level of significance (α = 0.05). Use of this alternative technique resulted in significantly lower tensile strength compared to the conventional technique (0.58 ± 0.12 vs. 1.08 ± 0.13 MPa; p<0.001). The technique presented here (alternative) could avoid the undesired removal of cemented cast posts or cores at the time of provisional prosthesis removal and ensures the cementation of extensive provisional prostheses with calcium hydroxide cement (AU)


O objetivo deste estudo foi descrever e caracterizar (utilizando o ensaio de tração) uma técnica alternativa de manuseio para o cimento de hidróxido de cálcio na cimentação de coroa temporária. No grupo tratado com a técnica convencional (n=10), as pastas base e catalisadora de um cimento de hidróxido de cálcio (Dycal) foram dispensadas na proporção de 1:1 e misturadas. O cimento foi então aplicado às superfícies cervicais internas da restauração provisória, e a restauração foi colocada sobre o dente preparado e mantido no local com pressão digital. No grupo tratado com a técnica alternativa (n=10), a pasta base do cimento de hidróxido de cálcio (Dycal) foi colocada no dente e a pasta catalítica foi inserida na coroa provisória. A prótese provisória foi colocada sobre o dente e mantida no local com pressão digital. Os valores de tração foram avaliados comparados entre os grupos pelo teste t de Student, com nível de significância de 5% (α = 0,05). O uso desta técnica alternativa resultou em resistência à tração significativamente menor em comparação com a técnica convencional (0,58 ± 0,12 vs. 1,08 ± 0,13 MPa; p <0,001). A técnica aqui apresentada (alternativa) poderia evitar a remoção indesejada de pinos ou núcleos fundidos no momento da remoção da prótese provisória e garantir a cimentação de próteses provisórias extensas com cimento de hidróxido de cálcio (AU)


Subject(s)
Calcium Hydroxide , Cementation , Dental Cements , Denture, Partial, Temporary , Tensile Strength , Materials Testing , Data Interpretation, Statistical
12.
Braz. dent. j ; 28(6): 738-743, Nov.-Dec. 2017. tab, graf
Article in English | LILACS | ID: biblio-888700

ABSTRACT

Abstract Cariostatic treatment has been shown to successfully arrest caries. However, it blackens the carious tooth structure. This study evaluated the effects of an experimental cariostatic agent with silver nanoparticles (Ag-Nano) using microhardness (MH) and microbiological tests. The cariostatic agents tested were: Saforide®, Cariestop®, Ancarie® and Ag-Nano. Sixty-six samples from deciduous enamel were submitted to initial (after pH cycling to obtain initial caries-like lesion) and final (after cariostatic application) MH testing and %MH values were calculated. After longitudinal sectioning, internal (I) MH was evaluated. Strains of Streptococcus mutans, Escherichia coli, and Enterococcus faecalis in brain-heart infusion culture were treated with the cariostatic agents. Agar diffusion tests (ADTs) were performed and minimum inhibitory concentrations were determined. The statistical tests used were: Kruskal-Wallis and Dunn (%MD; ADT; MIC) and ANOVA followed by Tukey's test (I-MH) (p<0.05). The %MH of Saforide® was significantly greater than that of Ag-Nano (p<0.05). Internal MH showed progressive improvement in the enamel remineralization for all cariostatic tested. In ADTs showed greater inhibition of S. mutans, E. faecalis, and E. coli by Saforide® than by Ancarie® and Ag-Nano. Ag-Nano was able to inhibit 100% microorganism growth at a lower concentration than required for the other agents. It was concluded that Ag-Nano treatment promoted remineralization of deciduous tooth enamel with initial caries-like lesion and bactericidal activity.


Resumo O tratamento com cariostático tem demostrado sucesso na paralização da cárie. No entanto, causa escurecimento da estrutura dental cariada. Este estudo avaliou os efeitos de um agente cariostático experimental com nanopartículas de prata (Ag-Nano) através de microdureza (MD) e testes microbiológicos. Os cariostáticos testados foram: Saforide®, Cariestop®, Ancarie® e Ag-Nano. Sessenta e seis amostras de esmalte decíduo foram submetidos a MD inicial (após ciclagem de pH para obtenção da lesão de cárie inicial) e final (após aplicação dos cariostáticos), e os valores da porcentagem (%) de MD foram calculados. Após secção longitudinal, a MD interna (I) foi avaliada. Cepas de Streptococcus mutans, Escherichia coli e E. faecalis foram cultivados em ágar infusão de cérebro e coração (BHI) e submetidos aos cariostáticos testados. Além disso, foram realizados teste de difusão em ágar (TDA) e avaliação da concentração mínima inibitória (CIM) dos cariostáticos. Os testes estatísticos usados foram: Kruskall-Wallis e Dunn (%MD; TDA; CIM) e ANOVA seguido de teste de Tukey (MD-I) (p<0.05). A %MD do Saforide® foi significativamente maior do que a de Ag-Nano (p<0,05). A MD interna apresentou melhora progressiva na remineralização do esmalte para todos os cariostático testados. Os resultados do TDA mostraram que S. mutans, E. faecalis e E. coli sofreram maior inibição pelo Saforide® (p<0,05), em relação ao Ancarie® e Ag-Nano. No entanto, para o teste de CIM o Ag-Nano foi capaz de inibir 100% dos microorganismos, em menor concentração do que os demais cariostaticos. Conclui-se que, o tratamento Ag-Nano foi capaz de promover remineralização do esmalte dental decíduo com lesão de cárie inicial e apresentou atividade bactericida.


Subject(s)
Humans , Anti-Infective Agents/pharmacology , Cariostatic Agents/pharmacology , Metal Nanoparticles , Silver/chemistry , Tooth Remineralization , In Vitro Techniques , Microbial Sensitivity Tests
13.
J. health sci. (Londrina) ; 19(3)31/10/2017.
Article in Portuguese | LILACS | ID: biblio-876140

ABSTRACT

Em endodontia, indicam-se substâncias quelantes para a remoção da lama dentinária. O objetivo deste estudo foi avaliar, in vitro, por meio do microcisalhamento, a resistência de união da resina composta com superfícies dentinárias tratadas com EDTA (17%) e quitosana (0,2%). De 30 coroas de dentes bovinos foram removidas as paredes palatina, mesial e distal, expondo a superfície dentinária da parede vestibular da câmara coronária, que abrasionada produziu a camada de esfregaço. Após, a superfície foi tratada, estabelecendo-se 3 grupos (n=10): G1 (controle) com aplicação de água destilada (1min); G2 com aplicação de EDTA (3 min.), e lavagem com água destilada (1 min.); e G3 com aplicação de quitosana (3 min.), lavagem com água destilada (1 min.). Na sequência foram aplicados 2 ml de NaOCl (2,5%), 2 ml de água destilada (1 min), armazenando-as em água destilada (37 °C). Retiradas da água destilada (24 h), fixaram ­se 3 tubos Tygon (1mmX1mm) na dentina após o condicionamento local com sistema adesivo convencional de 2 passos. Preenchidos com resina composta e após fotoativação, os tubos foram removidos obtendo-se cilindros que foram submetidos ao microcisalhamento em máquina de ensaio universal. Os resultados de resistência de união (MPa) foram submetidos a Análise de Variância e Tukey, com nível de significância 5%. Observou-se que a resistência de união de G2 e G3 foram equivalentes estatisticamente (p>0,05), porém significativamente maiores que em G1 (p<0,05). Conclui-se que quitosana e EDTA promovem resistência de união semelhante nas condições testadas. (AU).


In endodontics, chelating substances are indicated for smear layer removal. This study evaluated, by micro-shear, the bond strength between composite resin and dentin surfaces treated with EDTA (17%) and chitosan (0.2%). The palatal, mesial and distal walls were removed from 30 crowns of bovine teeth, to expose buccal dentin of coronary chamber, whose abrasion produced the smear layer. The surface was treated, considering 3 groups (n = 10): G1 (control) distilled water (1min); G2 EDTA application (3 min), and distilled water (1 min); and G3 chitosan application (3 min.), distilled water (1 min.). All groups received 2 ml of NaOCl (2.5%), 2 ml of distilled water (1 min), and then stored in distilled water (37 °C). After that (24 h), 3 Tygon matrix (1 mmX1 mm) were fixed to the dentin after surface storing them with a two-step adhesive system. Then, the matrixes were filled with composite resin, and once photoactivated, the matrix were removed resulting in cylinders that were submitted to micro-shear bond test in universal test machine. The results (MPa) were submitted to ANOVA and Tukey, with significance level of 5%. It was observed that G2 and G3 bond strength were statistically equivalent (p> 0.05), but significantly higher than G1 (p <0.05). It is concluded that chitosan and EDTA resulted in similar bond strength under the conditions tested. (AU).

14.
J. health sci. (Londrina) ; 19(4)30/10/2017.
Article in Portuguese | LILACS | ID: biblio-877738

ABSTRACT

Este estudo avaliou a necessidade e uso de prótese entre 504 idosos independentes, cadastrados nas Unidades Básicas de Saúde (UBS) do município de Londrina, Paraná. As características sociodemográficas foram também analisadas. A situação quanto às próteses dentárias foi avaliada a partir de informações sobre seu uso e necessidade nos arcos superior e inferior. As observações ao exame levaram em conta os códigos e critérios preconizados pela Organização Mundial de Saúde (OMS). As informações sociodemográficas foram obtidas pela aplicação de um formulário estruturado, avaliando: sexo, idade, nível de escolaridade, estado conjugal, tipo de moradia, número de pessoas na casa, renda familiar. A idade dos 504 idosos avaliados envolveu entre 60 e 75 anos, sendo a maioria entre 65 e 74 anos (54,2%), do gênero feminino (66,3%), de procedência rural (53,8%), cor branca (62,1%) e com até 4 anos de estudo (80,6%). Destes idosos, 15,1% não usam qualquer tipo de prótese, 24,6% usam em uma arcada e 60,3% usam algum tipo de prótese nas duas arcadas. Quanto à necessidade de prótese, observou-se que 21,6% não necessitam de qualquer tipo de prótese, 19,4% necessitam em uma arcada e a maioria (58,9%) necessita nas duas arcadas. Somente houve dependência, estatisticamente significante, entre as variáveis de necessidade de prótese dentária e gênero, cor da pele e procedência. Sendo assim, pode-se concluir que a prevalência de necessidade de prótese é acentuada e existe uma demanda populacional para reabilitação protética. (AU)


This study evaluated the need and use of prosthesis among 504 independent elderly, registered in the Basic Health Units (BHU) of the city of Londrina, Paraná. Sociodemographic characteristics were also evaluated. The situation regarding dental prosthesis was evaluated based on information about their use and need in the upper and lower arches. The observations were performed according to the codes and criteria recommended by the World Health Organization (WHO). The sociodemographic information was obtained by applying a structured form, evaluating: gender, age, educational level, marital status, housing type, number of people living in the residence, family income. The age of the 504-elderly studied was between 65 and 74 years (54.2%), female (66.3%), rural origin (53.8%), white skin color (62.1%) and up to 4 years of schooling (80.6%). Of these elderly, 15.1% do not use any type of prosthesis, 24.6% use only in one dental arch and 60.3% use some type of prosthesis in both arches. Regarding the need of prosthesis, it was observed that 21.6% do not require any type of prosthesis, 19.4% need in one arch and the majority (58.9%) needs in both arches. There was only statistically significant dependence among the variables of need for dental prosthesis and gender, skin color and origin. Thus, it can be concluded that the prevalence of need for prosthetic is high and there is a population demand for prosthetic rehabilitation. (AU)

15.
J. health sci. (Londrina) ; 19(4)30/10/2017.
Article in Portuguese | LILACS | ID: biblio-877749

ABSTRACT

Facetas cerâmicas fornecem resultados estéticos satisfatórios, preservando a estrutura dentária. A cerâmica dental pode melhorar a aparência estética e restabelecer a resistência e a função dos dentes. Nos dentes anteriores restaurados, as superfícies funcionais, por exemplo, em orientação anterior e lateral podem ser restauradas efetivamente. As características da cerâmica dental, como a estabilidade da cor e as propriedades mecânicas e ópticas, tornam este material uma boa escolha para restaurações indiretas, especialmente, quando são necessárias funções ótimas e a estética. Além disso, o dissilicato de lítio é uma cerâmica dental, que imita a estética e a resistência da estrutura dentária natural e foi utilizado no presente relato de caso clínico. (AU)


Ceramic veneers provide satisfactory esthetic outcomes while preserving the dental structure. Dental ceramics can both improve the esthetic appearance and reestablish the teeth's strength and function. In restored anterior teeth, functional surfaces, for example, anterior and lateral guidance, can be restored effectively. The characteristics of dental ceramics, such as color stability and mechanical and optical properties, make this material a good choice for indirect restorations, especially when optimum function and esthetics are required. Moreover, lithium disilicate is a dental ceramic that mimics the esthetics and strength of the natural tooth structure and it was used in the present clinical case report. (AU)

16.
Braz. dent. j ; 28(5): 618-623, Sept.-Oct. 2017. tab
Article in English | LILACS | ID: biblio-888680

ABSTRACT

Abstract The aim of this study was to evaluate the efficacy of applying sonic energy on microtensile bond strength and microhardness after the restoration process. A total of 40 human third molars were extracted. Class II cavities were prepared and restored with composite SonicFill or Filtek Z350 XT with and without the application of sonic energy. After the teeth were stored in water for 24 h, the teeth were sectioned into sticks (1.0 mm2) and subjected to tensile testing. For a depth Knoop hardness test, the samples were cut and indentations were made sequentially from the surface of the samples to the bottom of the samples in three intervals of 1 mm each. The samples were then subjected to a load of 50 g for 10 s. The results from the tensile (factors: placement system and composite) and hardness (factors: placement system, composite and depth) tests were subjected to the Kolmogorov-Smirnov normality test, followed by analysis of variance and Tukey's test (5% significance). For the placement system factor, higher bond strength was observed for the cavities that were restored with sonic energy (p < 0.001). For depth Knoop hardness, the hardness at 1 mm depth was significantly greater than that at 3 mm depth just for the restorations with Filtek Z350 XT composite without the application of sonic energy. Therefore, the use of sonic energy during the restorative process improved bonding, yet it did not markedly affect the depth hardness for both composites.


Resumo O objetivo deste estudo foi avaliar a eficácia da aplicação de energia sônica sobre a resistência de união à microtração e a microdureza após o processo de restauração. Um total de 40 terceiros molares humanos foram extraídos. Cavidades Classe II foram preparadas e restauradas com os compósitos SonicFill ou Filtek Z350 XT com e sem a aplicação de energia sônica. Após os dentes serem armazenados em água durante 24 h, foram seccionados em palitos (1,0 mm2) e submetidos a ensaio de tração. Para um ensaio de dureza Knoop de profundidade, as amostras foram cortadas e as penetrações foram feitas sequencialmente a partir da superfície para o fundo das amostras em três intervalos de 1 mm cada. As amostras foram então submetidas a uma carga de 50 g durante 10 s. Os resultados dos testes de tração (fatores: sistema de inserção e compósito) e dureza (fatores: sistema de inserção x compósito x profundidade) foram submetidos ao teste de normalidade Kolmogorov-Smirnov, seguido da análise de variância e do teste de Tukey (significância de 5%). Para o fator sistema de inserção, observou-se maior resistência de união para as cavidades que foram restauradas com energia sônica (p < 0,001). Para a dureza Knoop de profundidade, a dureza a 1 mm de profundidade foi significativamente maior do que a profundidade de 3 mm apenas para as restaurações com o compósito Filtek Z350 XT sem a aplicação de energia sônica. Portanto, o uso de energia sônica durante o processo restaurador melhorou a união, mas não afetou acentuadamente a dureza de profundidade para ambos os compósitos.


Subject(s)
Humans , Composite Resins/chemistry , Dental Restoration, Permanent/methods , Hardness Tests , Tensile Strength
17.
Acta odontol. latinoam ; 30(1): 13-18, 2017. tab
Article in English | LILACS | ID: biblio-907402

ABSTRACT

This study compared the surface detail reproduction anddimensional accuracy of molds after disinfection using 2% sodium hypochlorite, 2% chlorhexidine digluconate or 0.2% peracetic acid to those of molds that were not disinfected, forfour elastomeric impression materials: polysulfide (Light Bodied Permlastic), polyether (Impregum Soft), polydimethylsiloxane(Oranwash L) and polyvinylsiloxane (Aquasil Ultra LV). Themolds were prepared on a matrix by applying pressure, using aperforated metal tray. The molds were removed followingpolymerization and either disinfected (by soaking in one of thesolutions for 15 minutes) or not disinfected. The samples werethus divided into 16 groups (n=5). Surface detail reproductionand dimensional accuracy were evaluated using opticalmicroscopy to assess the 20 ­µm line over its entire 25 mm length. The dimensional accuracy results (%) were subjectedto analysis of variance (ANOVA) and the means were comparedby Tukey’s test (α=5%). The 20 ­µm line was completelyreproduced by all elastomeric impression materials, regardlessof disinfection procedure. There was no significant difference between the control group and molds disinfected with peraceticacid for the elastomeric materials Impregum Soft (polyether)and Aquasil Ultra LV (polyvinylsiloxane). The high­leveldisinfectant peracetic acid would be the choice material for disinfection.


Este estudo comparou a reprodução de detalhes da superfície e estabilidade dimensional de moldes obtidos após desinfecção utilizando hipoclorito de sódio 2%, digluconato de clorexidina 2%, ou ácido peracético 0,2% a moldes que não foram desinfetados com quatro elastômeros: polissulfeto (Light Bodied Permlastic), polieter (Impregum Soft), silicona reação porcondensação (Oranwash L) e silicona reação por adição (Aquasil Ultra LV). Os moldes foram preparados sobre matriz conten dolinhas de 20, 50 e 75 µm realizado sob pressão com moldeirade metal perfurada. Os moldes foram removidos após a polimerização e desinfetados (utilizando uma das soluções porimersão, armazenados em frascos fechados durante 15 minutos)ou não desinfetados. Assim, as amostras foram divididas em 16grupos (n=5). A reprodução detalhes da superfície e a precisão dimensional foram avaliadas usando microscopia óptica na linha 20 µm com 25 mm de comprimento, de acordo com a norma ISO 4823. Os resultados de precisão dimensional (%) foram submetidos à análise de variância (A NOVA) e as médias comparadas pelo teste de Tukey com 5% de nível de significância. A linha de 20 µm foi completamente reproduzida por todos os elastômeros, independentemente do processo de desinfecção. Não houve diferença estatisticamente significativa entre o grupo controle e moldes desinfetados com acido peracético para os elastômeros Impregum Soft (polieter) e Aquasil Ultra LV (siliconareação por adição). O desinfetante de alto nível ácido peracético seria o material de escolha para a desinfecção.


Subject(s)
Humans , Dental Impression Materials , Models, Dental , Dental Disinfectants/chemistry , Surface Properties , Analysis of Variance , Chlorhexidine/chemistry , Dimensional Measurement Accuracy , Edetic Acid/chemistry , Elastomers/classification , Microscopy/methods , Data Interpretation, Statistical , Siloxanes/classification , Sodium Hypochlorite/chemistry , Sulfides/classification
18.
Braz. dent. j ; 27(4): 458-462, July-Aug. 2016. tab, graf
Article in English | LILACS | ID: lil-794612

ABSTRACT

Abstract The purpose of this study was to evaluate the microshear bond strength of ceramic prosthetic structures reinforced by lithium disilicate cemented with resin cement under conditions of different surface treatments and adhesive systems. Seventy-two rectangular blocks of lithium disilicate (6.5 mm long × 5 mm wide × 1 mm thick) were fabricated, air abraded with 50-μm Al2O3 particles and divided into six groups (n=12) depending on the surface pretreatments. The groups were as follows: 10HF/S/SBM: 10% hydrofluoric acid etched for 20 s (10HF) + silane (S) + Adper Scotchbond Multi-Purpose (SBM); 10HF/S/SB: 10HF + S + Single Bond Universal (SB); 10HF/SBM; 10HF/SB; S/SBM and S/SB. Two 1-mm-long plastic tubes were placed on the specimens, filled with RelyX ARC resin cement and cured for 20 s per tube. The plastic tube was removed, and the microshear bond strength was tested. Data were submitted to analysis of variance and Tukey's tests (α=0.05). Fractured specimens were observed under optical microscopy. For both adhesives, the bond strengths (MPa) of groups treated with acid-etching and silane (10HF/S/SB: 24.82, 10HF/S/SBM: 24.90) were higher (p<0.001) than those of groups treated with acid-etching (10HF/SB: 16.47, 10HF/SBM: 19.94) only or only silane (S/SB: 18.42, S/SBM: 13.24). All groups showed a predominance of failure adhesive. The silanization should be a clinical step in cementing ceramic structures reinforced by lithium disilicate, even with the application of universal adhesive that contains silane in its formulation.


Resumo O objetivo neste estudo foi avaliar a resistência de união ao microcisalhamento de estruturas protéticas cerâmicas reforçadas por dissilicato de lítio cimentadas com cimento resinoso sob diferentes tratamentos de superfície e sistemas adesivos. Setenta e duas barras retangulares de dissilicato de lítio (6,5 mm de comprimento × 5 mm de largura × 1 mm de espessura) foram fabricadas, tratados com partículas de Al2O3 (50 μm) e dividido em seis grupos (n=12) dependendo dos pré-tratamentos de superfície. Os grupos foram como se segue: 10HF/S/SBM: condicionamento com ácido fluorídrico 10% durante 20 s (10HF) + silano (S) + Adper Scotchbond Multi-Purpose (SBM); 10HF/S/SB: 10HF + S + Single Bond Universal (SB); 10HF/SBM; 10HF/SB; S/SBM; e S/SB. Dois tubos plásticos cilíndricos de 1 mm de comprimento foram colocados sobre os espécimes, preenchidos com cimento RelyX ARC e fotoativado durante 20 s por tubo. Os tubos plásticos foram removidos e a resistência de união ao microcisalhamento foi testada. Os dados foram submetidos à análise de variância e ao teste de Tukey (α=0,05). Espécimes fraturados foram observados sob microscopia óptica. Para ambos os adesivos, a resistência de união (MPa) dos grupos tratados com condicionamento ácido e silano (10HF/S/SB: 24,82, 10HF/S/SBM: 24,90) foram superiores (p<0.001) aos grupos tratados com condicionamento ácido apenas (10HF/SB: 16,47, 10HF/SBM: 19,94) ou apenas silano (S/SB: 18,42, S/SBM: 13,24). Todos os grupos apresentaram uma predominância de falha adesiva. A silanização deve ser um passo clínico em cimentação de estruturas cerâmicas reforçadas por dissilicato de lítio, mesmo com a aplicação do adesivo universal que contém em sua formulação um silano.


Subject(s)
Dental Porcelain/chemistry , Materials Testing , Surface Properties
19.
J. health sci. (Londrina) ; 18(3): 183-187, 31/07/2016.
Article in English | LILACS | ID: biblio-831803

ABSTRACT

Avaliou-se a durabilidade da adesão de adesivos autocondicionantes à dentina após evaporação dos solventes com jato de ar frio e quente. Os sistemas adesivos Clearfil 3S Bond e OptiBond All-In-One foram aplicados em superfícies planas de dentina, a evaporação dos solventes feita com ar quente (60±2 o C) ou ar frio (20±2 o C), seguindo-se fotoativação (600mW/cm2 por 10 s) e restauração com compósito (3 x 2 mm). Após armazenagem em água destilada (24 horas / 37 o C), as amostras foram seccionadas para obtenção de paralelogramos de 0,8 mm2 para testar em tração (0,5mm/min) em 24 horas e 6 meses. Dois paralelogramos de cada grupo experimental foram preparados para observar a nanoinfiltração na interface com a dentina. Os valores médios da resistência adesiva (em MPa) de cada grupo foram tratados por Análise de Variância de três fatores e teste de Tukey (5%), sendo o dente a unidade experimental. Foi observada maior adesão após evaporação dos solventes com ar quente (p=0.000) no tempo de 24 horas de armazenagem (0.003). Não houve diferenças para o tipo de adesivo (p=0.343) e nem para a interação adesivo X tempo X temperatura de evaporação do solvente (p>0,05). Concluiu-se que a durabilidade da adesão foi influenciada pela temperatura de evaporação do jato de ar


To evaluate the bonding longevity of one-step self-etch adhesive systems to dentin, after solvent evaporation with warm or cold airstream. Clearfil 3S Bond and OptiBond All-In-One adhesives were applied on flat dentin surfaces, solvent evaporation was performed with a warm (60±2 o C) or cold air (20±2 o C), the surfaces were light cured (600mW/cm2 during 10 s), and blocks of compositeres min were built (3 x 2mm). After storage in distilled water (24-hour at 37 o C), the samples were sectioned into 0.8 mm2 sticks and tested in tensile (0.5 mm/min) at 24-hour and 6-month periods. Two sticks from each experimental group were prepared for nanoleakage observation of the bond interface. The mean bond strength values of experimental groups (in MPa) were subjected to a three- way Analysis of Variance and post-hoc Tukey´s test (5%), using tooth as the experimental unit. Higher bond strength was observed with warm air (p=0.000) for solvent evaporation, and 24 hour of water storage (0.003. No significant differences were observed for both the adhesive systems (p=0.343) and interactions.The bonding durability was influenced by the air temperature for solvent evaporation

20.
Braz. dent. j ; 27(1): 83-89, Jan.-Feb. 2016. tab, graf
Article in English | LILACS | ID: lil-777150

ABSTRACT

Abstract This study evaluated the bond strength (BS) of experimental resin cements formulated with different photoinitiators when activated by two kinds of light-curing units (LCUs) through a ceramic material. Seven resin blends with different camphorquinone (CQ) and/or phenylpropanedione (PPD) concentrations (weight) were prepared: C5: 0.5% CQ; C8: 0.8% CQ; P5: 0.5% PPD; P8: 0.8% PPD; C1P4: 0.1% CQ and 0.4% PPD; C4P1: 0.4% CQ and 0.1% PPD; C4P4: 0.4% CQ and 0.4% PPD. Two LCUs were used: one quartz-tungsten-halogen (QTH - 850 mW/cm²) and one light-emitting diode (LED - 1300 mW/cm²). The microtensile bond strength of each blend was assessed. Data were submitted to two-way ANOVA and Tukey's test (α=0.05). The BS values did not exhibit significant differences for LCUs, regardless of the photoinitiator type. Three cements showed significant differences: P5 and C5 had higher BS with QTH, and C4P1 with LED. For QTH, P5 showed the highest and C1P4 the lowest BS. For the LED, C4P1 showed the highest BS of all the cements. The results indicated that PPD was a viable alternative in the formulation of photocured resin cements, reducing or eliminating CQ that is yellowish without impairing the bond strength. Furthermore, both LED and QTH were effective in curing resin cements that contain PPD or CQ.


Resumo Este estudo avaliou a resistência de união (BS) de cimentos resinosos experimentais formulados com diferentes fotoiniciadores, quando ativados através de cerâmica, por dois tipos de fontes luminosas (LCUs). Foram preparadas sete formulações com diferentes concentrações em peso (wt) de canforquinona (CQ) e/ou fenilpropanodiona (PPD): C5: 0,5%CQ; C8: 0,8%CQ; P5: 0,5%PPD; P8: 0,8%PPD; C1P4: 0,1%CQ e 0.4%PPD; C4P1: 0,4%CQ e 0,1%PPD; C4P4: 0,4%CQ e 0,4%PPD. Duas LCUs foram usadas: uma com luz halógena (QTH - 850 mW/cm²) e uma com diodo emissor de luz (LED - 1300 mW/cm²). A BS foi avaliada por teste de microtração. Os dados foram submetidos a ANOVA a dois fatores e Teste de Tukey (α=0,05). Isolando o tipo de fotoiniciador, não houve diferenças significativas na BS. Três cimentos mostraram diferenças significativas: a BS foi maior para P5 e C5 com QTH; e para C4P1 com LED. Para a QTH, P5 exibiu a maior e C1P4 a menor BS. Para LED, C4P1 exibiu a maior BS de todos os outros cimentos testados. Conclusão: PPD é altamente viável em formulações de cimentos resinosos fotopolimerizáveis, reduzindo ou eliminando a CQ que é amarelada, sem comprometer a resistência de união. Além disso, tanto LED quanto QTH são efetivas para polimerizar os cimentos contendo PPD ou CQ.


Subject(s)
Composite Resins/chemistry , Curing Lights, Dental , Dental Bonding , Dentin/chemistry , Microscopy, Electron, Scanning
SELECTION OF CITATIONS
SEARCH DETAIL